DEFELSKO Certified Coated Metal Plates / Model: S1
Specifications
Details
Code | Ideal For | Approx. Thickness- Plate 1 | Approx. Thickness - Plate 2 | Approx. Thickness - Plate 3 | Approx. Thickness - Plate 4 | Coating/ Substrate |
Accuracy |
S1 |
PosiTector 6000 F, FS, FRS, FN, FNS, FNRS, FXS*, FNDS / PosiTest F & FM |
0 | 75 μm 3 mils |
250 μm 10 mils |
1500 μm 60 mils |
Epoxy on Steel (Ferrous) |
± 0.43 μm ± 0.017 mil |
S2 |
PosiTector 6000 F0S, F45S, F90S, F90ES / PosiTest DFT Ferrous & Combo |
0 | 75 μm 3 mils |
250 μm 10 mils |
1000 μm 40 mils |
Epoxy on Steel (Ferrous) |
± 0.43 μm ± 0.017 mil |
S3 |
PosiTest G & G / PosiPen A, B & C |
0 | 15 μm 0.6 mils |
40 μm 1.6 mils |
100 μm 4 mils |
Epoxy on Steel (Ferrous) |
± 0.43 μm ± 0.017 mil |
S4 | PosiTector 6000 FXS* | 0 | 75 μm 3 mils |
1000 μm 40 mils |
1900 μm 75 mils |
Epoxy on Steel (Ferrous) |
± 0.43 μm ± 0.017 mil |
A1 | PosiTector 6000 N, NS, NRS, FN, FNS, FNRS, FNDS | 0 | 75 μm 3 mils |
250 μm 10 mils |
1500 μm 60 mils |
Epoxy on Aluminum (Non-Ferrous) |
± 0.43 μm ± 0.017 mil |
A2 |
PosiTector 6000 NAS, N0S, N45S, N90S / PosiTest DFT Combo |
0 | 75 μm 3 mils |
250 μm 10 mils |
500 μm 20 mils |
Epoxy on Aluminum (Non-Ferrous) |
± 0.43 μm ± 0.017 mil |
A3 | PosiTector 100B, 200, 200B | 75 μm 3 mils |
125 μm 5 mils |
250 μm 10 mils |
500 μm 20 mils |
Epoxy on Aluminum (Non-Ferrous) |
± 0.43 μm ± 0.017 mil |
*PosiTector FXS probes with a range of 0-1500 um (0-60 mils) and Serial Numbers <361485 should use the S1 Standard.
All certified standards are supplied with a Certificate of Calibration traceable to NIST or PTB.
Plate Diameter: 38 mm (1.5'') Measurement Diameter: 25 mm (1'')
Certified coated metal plates and polystyrene blocks are ideal for verifying the accuracy and operation of coating thickness gages and are an important component in fulfilling both ISO and in-house quality control requirements.
Many organizations require verification of gage accuracy at the test site each time a coating thickness gage is put into service and at frequent intervals during use. Ideal for this purpose, DeFelsko certified coating thickness standards have measured values traceable to a National Metrology Institution.
- Used to verify the accuracy and operation of any Type 1 (mechanical) and Type 2 (electronic) magnetic, eddy-current or ultrasonic coating thickness gage
- Ideal for use in the calibration lab, in the field or on the factory floor
- Standards with steel or aluminum substrates consist of 4 plates mounted in a protective binder
- Polystyrene thickness standards consist of 4 blocks supplied in a rugged acrylic storage box
- Individually serialized for traceability to NIST or PTB - includes a Certificate of Calibration
- Certified and labeled in both Metric and Imperial units
Zero Plates available for both Certified Coated Metal Plates and Certified Polystyrene Blocks.
View more about DEFELSKO Certified Coated Metal Plates / Model: S1 on main site